Advanced Configuration

The following Advanced Operation parameters require that you have a controller that supports the advanced configuration command class.All On/All Off
All GE/Jasco lighting devices can be set to respond to ALL ON and ALL OFF commands in up to four different ways. Some controllers may not be able to change the response from its default setting. Please refer to your controller’s instructions for information on whether or not it supports the configuration function and if so, how to change this setting.


The four possible responses are:

  • It will respond to ALL ON and the ALL OFF commands (default).
  • It will not respond to ALL ON or ALL OFF commands.
  • It will respond to the ALL OFF command but will not respond to the ALL ON command.
  • It will respond to the ALL ON command but will not respond to the ALL OFF command.

 

Plug-In Smart Dimmer
Load Sensing
Load sensing is disabled when shipped from the factory. This feature can be enabled if desired. Setting parameter 29 to a value of 1 will enable the Load Sense function.
  • Parameter No: 29
  • Length: 1 Byte
  • Valid Values = 0 or 1 (default 0)
Note: When replacing a burned-out light bulb, the load sensing feature (if enabled) will automatically turn the light ON when the new bulb is installed even if the Z-wave module was previously turned OFF.
 
Dim Rate Adjustments
Both the number of steps (or levels) that the dimmer will change and the timing of the steps can be modified to suit personal preferences. The timing of the steps can be adjusted in 10-millisecond intervals. As an example, the default setting for parameter 8 is “3”. This means that the lighting level will change every 30 milliseconds when the Dim Command is received. A value of 255 would mean that the level would change every 2.55 seconds. Combined, the two parameters allow dim rate adjustments from 10 milliseconds to 4.2 minutes to go from maximum-to-minimum or minimum-to-maximum brightness levels.
 
1. When Receiving a Z-Wave Dim Command
  • Parameter 7 (number of steps or levels)
  • Parameter 8 (timing of the steps)
  • Length: 1 Byte
  • Valid Values:
    • Parameter 7 (default = 1) Valid Values: 1-99
    • Parameter 8 (default = 3) Valid Values: 1-255
2. Manual Control Dimming (pressing the Dimmer’s button)
  • Parameter 9 (number of steps or levels)
  • Parameter 10 (timing of the steps)
  • Length: 1 Byte
  • Valid Values:
    • Parameter 9 (default = 1) Valid Values: 1-99
    • Parameter 10 (default = 3) Valid Values: 1-255
3. When Receiving an All-On or All-Off Command
  • Parameter 11 (number of steps or levels)
  • Parameter 12 (timing of the steps)
  • Length: 1 Byte
  • Valid Values:
    • Parameter 11 (default = 1) Valid Values: 1-99
    • Parameter 12 (default = 3) Valid Values: 1-255

 

Plug-In Smart switch

NO ADVANCED PARAMETERS OUTSIDE OF ALL ON/ALL OFF CONTROL


 

Plug-In Outdoor Smart Switch

NO ADVANCED PARAMETERS OUTSIDE OF ALL ON/ALL OFF CONTROL


 

In-Wall Smart Outlet

LED Light
When shipped from the factory, the LED is set to turn ON when the connected light is turned OFF. This is the default setting and can be changed if your primary controller supports the node configuration function. To make the LED turn ON when the light is turned ON, change parameter 3’s value to “1”. To turn the LED OFF at all times, change parameter 3’s value to 2.

  • Parameter No: 3
  • Length: 1 Byte
  • Valid Values = 0, 1 or 2 (default 0)

 

In-Wall Smart Switch

LED Light
When shipped from the factory, the LED is set to turn ON when the connected light is turned OFF. This is the default setting and can be changed if your primary controller supports the node configuration function. To make the LED turn ON when the light is turned ON, change parameter 3’s value to “1”. To turn the LED OFF at all times, change parameter 3’s value to 2.

  • Parameter No: 3
  • Length: 1 Byte
  • Valid Values = 0, 1 or 2 (default 0)

Invert Switch
If the switch is accidentally installed upside down with “On” at the bottom and “Off” at the top, the default On/Off rocker settings can be reversed by changing parameter 4’s value to “1”.

  • Parameter No: 4
  • Length: 1 Byte
  • Valid Values = 0 or 1 (default 0)

Alternatively, the LED default setting can also be changed at the switch.
To disable the LED indicator:

  • Press the "ON" switch 3 times successively
  • Press the "OFF" switch 1 time

Use this same process to restore the original LED setting.


 

In-Wall Smart Dimmer
LED LIGHT
When shipped from the factory, the LED is set to turn ON when the connected light is turned OFF. This is the default setting and can be changed if your primary controller supports the node configuration function. To make the LED turn ON when the light is turned ON, change parameter 3’s value to “1”. To turn the LED OFF at all times, change parameter 3’s value to 2.

  • Parameter No: 3
  • Length: 1 Byte
  • Valid Values = 0, 1 or 2 (default 0) 

Invert Switch
If the switch is accidentally installed upside down with “On” at the bottom and “Off” at the top, the default On/Off rocker settings can be reversed by changing parameter 4’s value to “1”.

  • Parameter No: 4
  • Length: 1 Byte
  • Valid Values = 0 or 1 (default 0)

Dim Rate Adjustments
Both the number of steps (or levels) that the dimmer will change and the timing of the steps can be modified to suit personal preferences. The timing of the steps can be adjusted in 10-millisecond intervals. As an example, the default setting for parameter 8 is “3”. This means that the lighting level will change every 30 milliseconds when the Dim Command is received. A value of 255 would mean that the level would change every 2.55 seconds. Combined, the two parameters allow dim rate adjustments from 10 milliseconds to 4.2 minutes to go from maximum-to-minimum or minimum-to-maximum brightness levels.

 

1. When Receiving a Z-Wave Dim Command

  • Parameter 7 (number of steps or levels)
  • Parameter 8 (timing of the steps)
  • Length: 1 Byte
  • Valid Values:
    • Parameter 7 (default = 1) Valid Values: 1-99
    • Parameter 8 (default = 3) Valid Values: 1-255

2. Manual Control Dimming (pressing the Dimmer’s button)

  • Parameter 9 (number of steps or levels)
  • Parameter 10 (timing of the steps)
  • Length: 1 Byte
  • Valid Values:
    • Parameter 9 (default = 1) Valid Values: 1-99
    • Parameter 10 (default = 3) Valid Values: 1-255

3. When Receiving an All-On or All-Off Command

  • Parameter 11 (number of steps or levels)
  • Parameter 12 (timing of the steps)
  • Length: 1 Byte
  • Valid Values:
    • Parameter 11 (default = 1) Valid Values: 1-99
    • Parameter 12 (default = 3) Valid Values: 1-255

Alternatively, the LED default setting can also be changed at the switch.
To disable the LED indicator:

  • Press the "ON" switch 3 times successively
  • Press the "OFF" switch 1 time

Use this same process to restore the original LED setting.

 


In-Wall Smart Dimmer
LED Light
When shipped from the factory, the LED is set to turn ON when the connected light is turned OFF. This is the default setting and can be changed if your primary controller supports the node configuration function. To make the LED turn ON when the light is turned ON, change parameter 3’s value to “1”. To turn the LED OFF at all times, change parameter 3’s value to 2.

  • Parameter No: 3
  • Length: 1 Byte
  • Valid Values = 0, 1 or 2 (default 0)

Invert Switch
If the switch is accidentally installed upside down with “On” at the bottom and “Off” at the top, the default On/Off rocker settings can be reversed by changing parameter 4’s value to “1”.

  • Parameter No: 4
  • Length: 1 Byte
  • Valid Values = 0 or 1 (default 0)

Dim Rate Adjustments
Both the number of steps (or levels) that the dimmer will change and the timing of the steps can be modified to suit personal preferences. The timing of the steps can be adjusted in 10-millisecond intervals. As an example, the default setting for parameter 8 is “3”. This means that the lighting level will change every 30 milliseconds when the Dim Command is received. A value of 255 would mean that the level would change every 2.55 seconds. Combined, the two parameters allow dim rate adjustments from 10 milliseconds to 4.2 minutes to go from maximum-to-minimum or minimum-to-maximum brightness levels.

 

1. When Receiving a Z-Wave Dim Command

  • Parameter 7 (number of steps or levels)
  • Parameter 8 (timing of the steps)
  • Length: 1 Byte
  • Valid Values:
    • Parameter 7 (default = 1) Valid Values: 1-99
    • Parameter 8 (default = 3) Valid Values: 1-255

2. Manual Control Dimming (pressing the Dimmer’s button)

  • Parameter 9 (number of steps or levels)
  • Parameter 10 (timing of the steps)
  • Length: 1 Byte
  • Valid Values:
    • Parameter 9 (default = 1) Valid Values: 1-99
    • Parameter 10 (default = 3) Valid Values: 1-255

3. When Receiving an All-On or All-Off Command

  • Parameter 11 (number of steps or levels)
  • Parameter 12 (timing of the steps)
  • Length: 1 Byte
  • Valid Values:
    • Parameter 11 (default = 1) Valid Values: 1-99
    • Parameter 12 (default = 3) Valid Values: 1-255

Alternatively, the LED default setting can also be changed at the switch.
To disable the LED indicator:

  • Press the "ON" switch 3 times successively
  • Press the "OFF" switch 1 time

Use this same process to restore the original LED setting.

 


In-Wall Smart Switch Toggle Style

Invert Switch
If the switch is accidentally installed upside down with “On” at the bottom and “Off” at the top, the default On/Off rocker settings can be reversed by changing parameter 4’s value to “1”.

  • Parameter No: 4
  • Length: 1 Byte
  • Valid Values = 0 or 1 (default 0)

Alternatively, the LED default setting can also be changed at the switch.
To disable the LED indicator:

  • Press the "ON" switch 3 times successively
  • Press the "OFF" switch 1 time

Use this same process to restore the original LED setting.


 

In-Wall Smart Dimmer Toggle Style
Invert Switch
If the switch is accidentally installed upside down with “On” at the bottom and “Off” at the top, the default On/Off rocker settings can be reversed by changing parameter 4’s value to “1”.

  • Parameter No: 4
  • Length: 1 Byte
  • Valid Values = 0 or 1 (default 0)

Dim Rate Adjustments
Both the number of steps (or levels) that the dimmer will change and the timing of the steps can be modified to suit personal preferences. The timing of the steps can be adjusted in 10-millisecond intervals. As an example, the default setting for parameter 8 is “3”. This means that the lighting level will change every 30 milliseconds when the Dim Command is received. A value of 255 would mean that the level would change every 2.55 seconds. Combined, the two parameters allow dim rate adjustments from 10 milliseconds to 4.2 minutes to go from maximum-to-minimum or minimum-to-maximum brightness levels.

 

1. When Receiving a Z-Wave Dim Command

  • Parameter 7 (number of steps or levels)
  • Parameter 8 (timing of the steps)
  • Length: 1 Byte
  • Valid Values:
    • Parameter 7 (default = 1) Valid Values: 1-99
    • Parameter 8 (default = 3) Valid Values: 1-255

2. Manual Control Dimming (pressing the Dimmer’s button)

  • Parameter 9 (number of steps or levels)
  • Parameter 10 (timing of the steps)
  • Length: 1 Byte
  • Valid Values:
    • Parameter 9 (default = 1) Valid Values: 1-99
    • Parameter 10 (default = 3) Valid Values: 1-255

3. When Receiving an All-On or All-Off Command

  • Parameter 11 (number of steps or levels)
  • Parameter 12 (timing of the steps)
  • Length: 1 Byte
  • Valid Values:
    • Parameter 11 (default = 1) Valid Values: 1-99
    • Parameter 12 (default = 3) Valid Values: 1-255

Alternatively, the LED default setting can also be changed at the switch.
To disable the LED indicator:

  • Press the "ON" switch 3 times successively
  • Press the "OFF" switch 1 time

Use this same process to restore the original LED setting.


 In-Wall Smart Fan Control

Invert Switch
If the switch is accidentally installed upside down with “On” at the bottom and “Off” at the top, the default On/Off rocker settings can be reversed by changing parameter 4’s value to “1”.

  • Parameter No: 4
  • Length: 1 Byte
  • Valid Values = 0 or 1 (default 0)

Portable Smart Motion Sensor

Introduction
This parameter list is applicable to both 35211 (3 Sensor Model) and 34193 (Motion Only Model), except parameter 24 which is only applicable to 35211.

 

“Basic Set”, “Notification” and “Basic Report”
Changing Parameter NO.20 can let Multi Sensor (PIR & battery operated) send out “Basic Set” command or “Basic report” command or “Notification” report to Z-Wave devices.Parameter No.: 20

Length: 1 Byte
Valid Values = 1, 2 and 3 (default: 1)

  • Value is 1: Multi Sensor will send out “Notification” report. “Notification” report is just a message and it will not turn the Destination Z-Wave device ON/OFF.
  • Value is 2: Multi Sensor will send out “Basic Set” command and turn Destination Z-Wave device ON/OFF
  • Value is 3: Multi Sensor will send out “Basic Report” command.

PIR Sensitivity Setting
We can modify the sensitivity of PIR if changing the value in parameter No13

Parameter No:13
Length: 1 byte
Valid value: 1, 2 and 3 (Default Setting is 3, High Sensitivity)1 – Low Sensitivity
2 – Medium Sensitivity
3 – High Sensitivity

 

PIR Timeout Duration Setting
Parameter No:18

Length: 1 byteValid Value: 1~60, 255 (The default setting is 4, 4 minutes)
255 – 5 seconds (Test Mode)
1 – 1minute

60 – 60 minutes 

 

Enable & Disable the LED indication when PIR Trigger and after timeout:

Parameter No: 28
Length 1 byte
Valid Value 0, 1 (Default 1: Enable)0 – Disable
1 – Enable (default) 

 

Enable & Disable the PIR Sensor
Parameter No: 6

Length 1 byte
Valid Value 0, 1 (Default 1: Enable)0 – Disable
1 – Enable (default) 

 

Temperature and Light Sensor Sensing Frequency Setting

ONLY APPLICABLE TO 35211
Parameter No: 24

Length 1 byte
Valid Value 5-60 (The default setting is 60, 60 minutes)5 = 5 minutes

60 = 60 minutes